The load
We use typical, editable values. None is measured in your home.
| Load | Average | Hours | Energy per day |
|---|---|---|---|
| Full-size fridge (medium confidence) | 54.2 W | 24 | 1,300 Wh |
| Router and modem (medium) | 10 W | 24 | 240 Wh |
| LED lights, 4 bulbs (medium) | 36 W | 6 | 216 Wh |
| Laptop charging (low) | 60 W at 50% duty | 4 | 120 Wh |
| Total before losses | about 1,880 Wh |
From 1,880 Wh to a battery size
Losses come next. With 85% inverter efficiency the load becomes about 2,208 Wh at the battery. Add the inverter’s idle draw: 10 W is 240 Wh over a day, 15 W is 360 Wh. Then divide by 90% usable depth.
- With a 10 W idle draw: (2,208 + 240) / 0.90 = about 2,720 Wh.
- With a 15 W idle draw: (2,208 + 360) / 0.90 = about 2,850 Wh.
So a 2,000 Wh unit does not make a full day, and a nameplate 3,000 Wh unit is the first class that does. The table below runs this for every model, with its own idle draw.
What the result means
Most of the energy goes to the fridge. If you have to cut something, cut the laptop and lights first. Dropping to the fridge and router only needs about 2,300 Wh, which is still above a nameplate 2 kWh unit.
Two checks matter more than the Wh. The inverter has to start the fridge, so read will a power station start my fridge. And a “Marginal” result means less than a 10% margin, which a warm kitchen can erase.
Measure first
If your fridge draws more than our figure, the answer changes. A plug-in watt meter on the fridge for 24 hours takes the guesswork out. Then use the calculator with your number.