Why a fridge is hard to start
A compressor is a motor. A motor starting from a standstill pulls far more current than it does once it is spinning. For a typical full-size fridge we use a start figure of 1,300 W, against a running draw near 54 W average. That number is third-party and carries medium confidence, because makers do not print it on the label.
The power station’s inverter has two ratings: continuous watts and surge watts. Both have to hold. The surge rating must cover the fridge’s start plus anything else already running. The continuous rating must cover everything running together afterward.
The “lifting” trap
Some makers publish a surge figure measured for resistive loads, such as a kettle, in a “lifting” or “power lifting” mode. It does not describe a motor start. The Bluetti manual for the Elite 200 V2, for example, lists Power Lifting among its modes.
For any unit where the surge figure is missing or is a lifting figure, our planner does not assume it covers a compressor. It checks continuous watts only and says “motor start not published”. That is not a pass. It means the result is unknown, and you should test with your own fridge, ideally while the return policy still applies.
How to read the table
- Fits or Marginal: the unit passes capacity, continuous watts and surge for the setup shown.
- No, cannot start the motor: the surge rating, or the continuous rating for lifting-only units, is below the start figure.
- No, not enough Wh: it starts the fridge but cannot run it for 24 hours.
The calculator lets you change the start figure to match your fridge.
If yours will not start
- Plug the power station into the fridge before anything else, so no other load adds to the surge.
- Try a soft-start accessory sold for compressors. We have not tested these and make no claim.
- Move to a unit with a published surge rating well above the fridge’s start figure.